| ▲ | ink_13 38 minutes ago | |
This doesn't explain why the system doesn't run "backwards". In the illustration, before the trigger is pulled, the ball seals against the upper chamber and leaves the piston open to the straw. So why does pressing the piston cause the ball to be pushed into the straw instead of pushing fluid down the straw? It would appear that adding pressure would only push the ball against the upper chamber more. And then at the end of the stroke, now the ball is sealing the straw and there's an open path through the upper chamber. So why doesn't the piston refill with air? | ||
| ▲ | jrflo 14 minutes ago | parent [-] | |
That's true, the animation is a bit confusing. I think in reality the ball is actually seated against the top of the straw at rest, and gets lifted up when there's suction force when the plunger is released. Gravity is returning the ball to being seated once the chamber is filled. Typically check valves have a spring return on the ball/sealing face, but gravity is probably used as a cost saving measure: https://en.wikipedia.org/wiki/Check_valve | ||