Remix.run Logo
▲ diimdeep 3 hours ago

Not passive, noise pollution.

    Specifically, the left speaker transmits C-FMCW chirps sweeping from 18kHz to 21 kHz, while the right speaker transmits in the range of 21.5 kHz to 24.5 kHz. Each speaker transmitsC-FMCW chirps with  = 600 samples per chirp. With a 50 kHz sampling rate, the sweep period for each chirpis 600/50000 = 0.012 sec (12 milliseconds). Assuming a speed of sound of 343 m/s at room temperature (20◦C),and following the formula provided in 2, the resolution of the EchoMotion sensing system is approximately 0.343cm (or 3.43 mm), and the sensing range is about 205.8 cm (approximately 2 m).
https://dl.acm.org/doi/epdf/10.1145/3832001
▲ninjalanternshk an hour ago | parent | next [-]

This was done with existing watch speakers and microphones. Wouldn’t ultrasound-specific speakers work better and be inaudible?

▲varispeed an hour ago | parent | prev [-]

Are these loud? If so I could imagine having many people wearing these would be unbearable. I can hear very well to about 20-21kHz.