| ▲ | CGMthrowaway 2 days ago | |
What is the advantage of this over just sticking a merv13 in your HVAC and running the fan for 15minutes every hour? (assuming it's rated for merv13) | ||
| ▲ | rainbowzootsuit a day ago | parent | next [-] | |
One issue beyond the flow rate others have noted is that if the fan doesn't cycle with the evaporator coil when in cooling conditions the wet coil will re-evaporate the water that is on it which will give higher humidity in the space. This is a climate and season dependent issue. | ||
| ▲ | sailfast 2 days ago | parent | prev | next [-] | |
For me, it just doesn’t remove the particulates fast enough when they’re quite dense outside or the house is porous. Better sealed homes might have better luck - it should work ok - but the best way to breathe filtered air quickly is to stick your head right above a filter. | ||
| ▲ | gojomo 2 days ago | parent | prev | next [-] | |
You can drop a boxfan-filter combo anywhere, even where there's no forced-air HVAC. | ||
| ▲ | xgulfie 2 days ago | parent | prev | next [-] | |
A box fan in a room will usually give you more air changes than typical HVAC | ||
| ▲ | schiffern 2 days ago | parent | prev [-] | |
Typical flow rates for HVAC systems are ~1 air change per hour, but to effectively filter the air faster than the dirty air leaks in, you need about 5 air changes per hour (AHAM recommendation). If using the HVAC, run the fan continuously, and ideally use the 1" 3M 1900 filter. Other brands or models (including the supposedly 'better' 4" 3M 1900 filters) have fewer pleats, which works out to smaller surface area and worse airflow resistance. Check BJs website, usually they're $10/filter in a 4-pack. Typically these need replacement every 3 months. The only way to really mess it up (and possibly break your HVAC system) is to completely forget to replace the filters, so I try to set redundant phone alerts with different family members. | ||