| ▲ | chneu 12 hours ago | |
This is the kind of stuff that municipalities and counties absolutely hate. Reporting this stuff generally matters and will get taken care of. When reporting, if the work of citing standards is done, it makes the report much more likely to go through and have action taken. | ||
| ▲ | walrus01 12 hours ago | parent [-] | |
In particular 222g, 222h and such have a "reliability factor", which can be summed up as, in a worst case scenario if it completely falls over, within its fall radius, is it going to hit anything or kill anyone? For example, a self-supporting steel monopole in the middle of a field, that if it falls over is going to hit some corn has a very low reliability factor. Even if it has been engineered to withstand the worst case 120 mph wind with extensive rime ice loading. On the other hand, if you have a 40 or 50 ft steel pole that's within the highway right away and it might fall over into traffic moving at 70 mph, that's a whole other question. 222G and H and similar do not cover scenarios like being hit by a 5 ton or 10 ton truck, I am not familiar with, but presumably there are also engineering standards for designing poles within the highway right-of-way that have to be able to withstand a certain sort of hit by a vehicle. Or being protected by a certain engineering standard of bollard. | ||