| ▲ | ProllyInfamous 2 hours ago | |||||||||||||||||||||||||
Interestingly, TVA/EPB/Lowes [7] never asked for our swaps (I threw all four oldtanks away). [7] not Home Depot; AOSmith -eligible, not Rheem (can no longer edit abovepost) ---- Didn't know about the gas disqualifier... or the great URL/reference (thanks)! For future TVA homeowner installers: the website seems to indicate that you MUST use an approved contractor for the rebate — at least December 2025, in EPB/Chatt, this was not required: just had to go to Hixson Lowes and have them look up address and then paid (w/ delivery, not in-stock). ---- Less than a decade ago, I helped install a 38kW [•] tankless/instaHot heater (¡¡¡ that's three 240v40a two-pole circuitbreakers !!!) into a beautiful new home. Homeowner is actively doing his part not maintaining the unit in eventual hopes of justify purchasing a new heatpump waterheater. Godspeed. [•] I think technically it's 28kW -rated (there's a consumer-installed limit, w/o boilermaker license), but the circuits support more w/o 80% derating applied | ||||||||||||||||||||||||||
| ▲ | quickthrowman an hour ago | parent [-] | |||||||||||||||||||||||||
> I think technically it's 28kW -rated (there's a consumer-installed limit, w/o boilermaker license), but the circuits support more w/o 80% derating applied A tankless water heater is not considered a continuous load so there’s no need to apply the 80% rule. A 60A 2P breaker will have a trip curve that results in a thermal trip for just under 100% of rated current in around 2-3 hours. The fast acting part of the trip curve is magnetic, longer duration trips are thermal. Here’s a link to a Square D breaker guide: https://ressupply.com/documents/square_d/QO_and_QOB_Circuit_... The trip curve on page 25 of the pdf applies to Square D QO plug-in (residential breakers are usually plug-in, commercial are bolted on) 2-pole breakers rated 120/240V from 45A-60A. Find the 1 (times rated current) at the bottom and follow it up the chart until it intersects with the black area of the trip curve, that is approximately when the breaker will trip at 100% of its rated ampacity. Look at the left hand side to see the time in seconds that it will trip in. It’s hard to see exactly where it intersects, but it’s somewhere between 7000-10000 seconds, or 2-3 hours. So, you need to apply the 80% rule to continuous loads because breaker trip curves are adjusted so the thermal overload trips in 3 or fewer hours at 100% of rated ampacity. If you look at .8 times rated load, the line never intersects the trip curve. Here’s a manual for an A.O. Smith tankless water heater: > https://assets.hotwater.com/damroot/Original/1000/100306523.... On page 10, the 4 element, 7kW per element unit draws 58.33A per 60A breaker, 7000/240 = 29.167A, two elements a piece for 58.33A per 60A breaker. It’s lot cheaper to wire up a 28kW electric heater if you have 480V three-phase, it’s only 28000/480/1.732 = 33.68A, all you need is a 35A 3P breaker, three #10s and a #10 ground. 240V single phase needs two 60A 2P breakers, four #6s and two #10 grounds, or if it was a single-point connection, one 125A 2P breaker, two #1/0s and a #6 ground. | ||||||||||||||||||||||||||
| ||||||||||||||||||||||||||