747fulloftapes 3 hours ago

Agreed!

I spent a few years getting flown out around the world to service gear at different datacenters. I learned to pack an IEC 60320 C14 to NEMA 5-15R adapter cable and a dumb, un-protected* NEMA 5-15R power strip. While on-site at the datacenters, an empty PDU receptacle was often easy to find. At hotels, I'd bring home a native cable borrowed from or given to me by the native datacenter staff or I'd ask the hotel front desk to borrow a "computer power cable," (more often, I'd just show them a photo) and they generally were able to lend me one. It worked great. I never found a power supply that wasn't content with 208 or 240V.

Example adapters: https://www.amazon.com/dp/B0FD7PHB7Y or https://www.amazon.com/dp/B01IBIC1XG

*: Some fancier power strips with surge suppression have a MOV over-voltage varistor that may burn up if given 200V+, rendering the power strip useless. Hence, unprotected strips are necessary.